Data Centre

Newsletter Sign-up

When to contact us?
Contact us today to discuss your inital requirements with one of our industry-leading consultants.

Data Centre – Slough, UK

 

FACILITYUPS Room

  • Data Centre floor space is approximately 5,000 square meters of raised floor
  • Site is manned 24x7x365 with Rackspace Operations personnel
  • OEM service/maintenance contracts on all facility infrastructure systems
  • SSAE16 compliant

 

SECURITY

  • Physical access to devices within Rackspace data centres is restricted to authorized Rackspace personnel
  • Card reader and biometric access required to enter facility
  • Card reader access required to enter data centre floor
  • Security cameras recorded by digital video recorder
  • Bomb proof film installed behind all windowed areas
  • Fully fenced perimeter

 

POWER

  • 100% renewable energy
  • Facility rated at 1.75kW per square meter or 3.5kW per rack
  • Two separate 15 MVA utility feeds provide power to the DC

 

 

 GeneratorsUPS (Uninterrupted Power Supply)

  • Four 1,200 kW Chloride UPS Net90 Clusters (N+1 configuration), expandable to 1,600 kW per Cluster 
  • Two 1,000 kW Chloride UPS Trinergy Clusters (modular N+1 configuration), expandable to 1,600 kW per Cluster 
  • 78 UPS power distribution panels 
  • UPS-fed panels are fully redundant
  • UPS provides instantaneous conditioned power for facilities until generator synchronization; transfer of power is automatic 
  • 10 minutes battery life at peak load 

 

GENERATOR

  • Six 2.25 MVA AVK diesel generators (N+1 configuration), expandable to eight
  • Generators activate and fully synchronize within 60 seconds
  • Each generator has its own supply system with a total of 60,000 litres on site
  • Fuel suppliers under contract to deliver fuel within 4 hours
  • 36-hour on site fuel capacity under full load

 

HVAC

  • 1,461,843 m³/h of cooling capacity
  • One Hundred and Four CRACs computer room air handling units (N+25% configuration)
  • Seven 1,500 kW RC Group centrifugal chillers w/VSD (N+1 configuration), expandable to eight
  • Six chilled water loop pumps, and condenser water loop pumps (N+1 configuration)

 

FIRE PROTECTION

  • Early Smoke Detection (VESDA)
  • Dry pipe pre-action fire suppression system

 

PDu's and CRAC unitsFACILITY MONITORING

  • NARC – Network monitoring software
  • Trend Facility Monitoring System (BMS)
  • C-Matic Power Management System allows real time monitoring and trending of power utilisation

 

 

CUSTOMER ACCESS

  • Customers retain administrative control of their leased servers.
  • Rackspace retains control of dedicated networking hardware such as firewalls and load balancers
  • Console level access is provided via Terminal Services of SSH over VPN, depending upon platform

 

BACKUP AND RECOVERY

  • Fully managed backup to centralized storage is available; offsite tape rotation is optional

 

NETWORK INFRASTRUCTURE

  • Redundant Cisco 3-tier LAN Architecture

 

ChillersPHYSICAL CONNECTIVITY

  • Multiple fibre carriers
  • Copper and fibre installed and terminated to onsite demarcation

 

TRANSIT

  • Multiple Tier-1 Service Providers
  • 10-Gigabit Ethernet per carrier (multiple gigabits of total
  • bandwidth available)

 

ROUTING

  • Redundant Cisco 6500 Series and ASR 9000 Series Switches for edge and core routing
  • Internap FCP route optimization

 

SWITCHING

  • Cisco 3550/3750/4948 Series Switches for aggregation
  • Cisco 2950/2960/2970 Series Switches for distribution